Waters Vials, Caps, Containers & Collection Plates
255 productsThis collection brings together the small—but critical—consumables that keep your LC/LC-MS workflow clean, consistent, and efficient. From 12 × 32 mm autosampler vials and matching caps/septa to certified GL45 solvent containers and 96-well collection plates, each item is designed to reduce background, protect analytes, and integrate smoothly with Waters systems.
What’s Included: Vials, Caps & Septa, Inserts, Containers, Collection Plates
Every step from sample storage to autosampler injection and fraction collection has a purpose-built piece of hardware. Below is a practical overview so you can see what belongs where in a typical method—and why each choice matters for data quality and throughput.
-
Autosampler Vials (glass & PP) – 12 × 32 mm formats for 2 mL/1.5 mL fills, plus low-volume and max-recovery options. LC/GC- and LC/MS-certified lines help minimize extractables and carryover.

- Caps & Septa – Color-coded, screw 9-425 closures with solid or preslit PTFE/silicone septa for clean resealing and reliable needle piercing. TruView™ and LCMS variants match vial lines.

-
Vial Inserts – Glass or PP, with/without springs, to reduce dead volume and support micro-fills (e.g., 300 µL).
-
Certified Containers (GL45) – Ultra-clean Type I borosilicate bottles (e.g., 500 mL, 1 L) with low TOC specs for mobile phases and standards. Matching multi-port caps available.

- Collection Plates & Seals – 96-/384-well PP plates (350 µL to 2 mL) for fraction collection and high-throughput handling, with heat-seals and cap mats to suit solvents and storage.

How to Choose: Material, Volume, Closure & Autosampler Fit
Choosing well is about matching chemistry and mechanics. First, pair material to solvent/analyte (glass vs PP, low-adsorption options). Then, size volume/insert to your fill level. Finally, confirm closure and dimensions match your autosampler/collector hardware.
Quick selection matrix
Scenario | Recommended Material | Volume/Format | Closure/Septa | Notes |
---|---|---|---|---|
Routine LC quant | Clear glass vial | 1.5–2 mL (12 × 32 mm) | 9-425 screw, PTFE/silicone (solid) | Balanced cleanliness & resealability |
Light-sensitive analytes | Amber glass vial | 1.5–2 mL | 9-425 screw, PTFE/silicone (solid) | Added UV protection |
Trace-level LC/MS | LC/MS-certified glass | Max-recovery or Qsert | 9-425 screw, preslit septum | Low background; easier needle penetration |
High organic/adsorption-prone | PP vial/insert | 300–700 µL | Screw cap, PTFE/silicone | Avoids glass interaction for certain matrices |
Fraction collection | PP plates | 350 µL–2 mL wells | Heat-seal or cap mat | Choose well depth & seal by solvent/storage |
Mobile phase storage | Type I glass container (GL45) | 500 mL / 1 L | Multi-port GL45 caps | Low TOC; route inlet/waste safely |
Materials & Cleanliness for LC/LC-MS: Glass vs PP, Low-Adsorption Options
Material impacts both analyte recovery and background noise. Type I borosilicate glass is the default for most methods; amber variants add UV protection. Polypropylene helps when glass interaction is a risk or when aggressive rinsing cycles are used. Certified lines (LC/GC, LC/MS, TruView™) are tested for cleanliness to reduce ghost peaks and ion suppression.
At-a-glance considerations
- Glass (clear/amber): Dimensional stability; broad solvent compatibility; ideal with solid or preslit PTFE/silicone septa.
-
PP (vials/inserts/plates): Good for adsorption-sensitive analytes and plate workflows; confirm seal type for organic content and storage temperature.
waters.com - Certified Containers (GL45): Low TOC reservoirs help prevent background in high-sensitivity LC/LC-MS.
Fit & Compatibility with Waters Autosamplers & Fraction Collectors
Mechanical fit ensures repeatable injections and clean fractions. Confirm vial geometry (e.g., 12 × 32 mm), neck finish (9-425 screw, 11 mm crimp/snap), and insert height. For plates, use the pre-programmed ANSI 96/384 geometries and choose well depth to minimize residual volume at your needle offset. Containers should use GL45 threads with appropriate caps/tubing.
Compatibility notes
-
Vials: certified kits are available with matched caps/septa, including max-recovery and Qsert options for low residues.
-
Plates: 96-well 350 µL, 700 µL, 1 mL and 2 mL square-well formats are supported; seals include polyester/aluminum heat-seals and adhesive films.
- Containers: 500 mL/1 L certified bottles pair with multi-port GL45 caps for safe inlet/waste routing.
Featured Models & Specs: Waters Certified Vials, Caps/Septa, Inserts & Plates
To help you start fast, here’s a representative cross-section that covers the most common tasks. Each SKU links to a compatible category family so you can expand as your method evolves.
Catalog # | Type | Material | Volume/Format | Closure/Septa | Cleanliness | Notes |
---|---|---|---|---|---|---|
186004902C | Screw-neck vial (kit) | Clear glass | 15 × 75 mm | With cap, PTFE/silicone | LC/GC-certified | General LC/GC workflows |
186004903C | Screw-neck vial (kit) | Clear glass | 15 × 75 mm | With cap, preslit PTFE/silicone | LC/GC-certified | Easier needle entry |
186001131C | Qsert vial (kit) | Amber glass | 12 × 32 mm / 300 µL | With cap, preslit | LC/GC-certified | Low volume + light protection |
600000749CV | Max-recovery vial (kit) | Clear glass | 12 × 32 mm / 1.5 mL | With cap, PTFE/silicone | LC/MS-certified | Low background for LC/MS |
186002626 | Screw-neck vial | PP | 12 × 32 mm / 300 µL | — | — | Adsorption-sensitive matrices |
WAT094170 | Low-volume insert | Glass + spring | 6 × 29 mm / 300 µL | — | — | Micro-fills, stable pickup |
186005829 | Cap & preslit septum | PTFE/silicone | 12 × 32 mm | 9-425 screw | For LC/MS-certified vials | Light-blue code |
186002643 | 96-well plate | PP, round | 350 µL/well | Heat-seal/cap mat options | — | Low residual volume |
186005837 | 96-well plate | PP, round | 700 µL/well | Heat-seal/cap mat options | — | Deeper wells for prep |
186002482 | 96-well plate | PP, square | 2 mL/well | Heat-seal/cap mat options | — | High-volume fractions |
186007090 | Certified container | Type I glass (GL45) | 500 mL | GL45 cap | Low TOC | Mobile-phase grade |
186007089 | Certified container | Type I glass (GL45) | 1 L | GL45 cap | Low TOC | Mobile-phase grade |
Applications & Workflows: Sampling, Storage & Fraction Collection
Each item earns its keep when placed in a real method. Think of vials as the gateway to repeatable injections, plates as the backbone of prep/fraction work, and certified containers as the silent partner protecting your baselines in sensitive LC/LC-MS assays.
- Batch quant & method development: Pair certified glass vials with preslit caps to ensure consistent needle penetration and resealing across large runs. Low-volume/Qsert options minimize headspace for small-sample work.
- Semi-prep & purification: Route defined time or MS-triggered fractions into 96-well plates sized for your downstream evaporation and reconstitution steps; select seals by solvent and storage horizon.
- Mobile-phase & standards: Use low-TOC GL45 containers to reduce ghost peaks and keep tubing organized with multi-port caps.
FAQs: HPLC/LC-MS Vials, Caps & Septa, Inserts, and Collection Plates
Q1: When should I choose preslit vs solid septa?
Preslit PTFE/silicone lowers piercing force and improves resealability for repeated injections; solid septa resist vapor loss a bit better for storage. Match the cap to the vial line (LC/GC, TruView™, LC/MS) for predictable performance.
Q2: Do 12 × 32 mm vials always hold 2 mL?
They’re commonly used at ~1.5–2.0 mL, but “max-recovery” geometries are specified by manufacturer; check the stated capacity (e.g., 1.5 mL) and choose inserts for micro-fills.
Q3: Which plate format minimizes residual volume?
Waters’ 96-well 350 µL and 700 µL plates are designed with well depths that pair to autosampler needle offsets; use the recommended ANSI geometries and seals to keep residuals low.
Q4: Why certified solvent containers instead of generic bottles?
Low-TOC certified containers reduce background and spurious peaks in high-sensitivity LC/LC-MS—especially important when methods push detection limits.
Related Waters Collections: Columns, Sample Prep, Standards & Reagents
These pages round out the same workflow: method building on columns, clean-up with SPE/filtration, and reference materials for qualification. Linking them keeps procurement and validation straightforward across teams and instruments.
Talk to Iright: Request a Quote & Compatibility Check
Choosing the right combination is faster when you have a partner who lives in both chromatography and procurement. Tell us your solvent system, target volume, closure preference, and autosampler/collector model—we’ll return a compatible short-list, lead times, and bundle pricing, backed by Iright’s track record serving regulated and research labs.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make any payment before confirmation.
3. Minimum order value of $1,000 USD required.
4. 100% prepayment required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924