Filtrar

    Thermo Fisher PCR Equipment & Supplies: Instruments, Master Mixes & Plastics

    1634 products

    From routine cloning to high-stakes quantification, Thermo Fisher’s PCR portfolio covers instruments, master mixes, enzymes, probes, plastics, and application-ready kits so you can build reliable DNA/RNA workflows end-to-end. As an authorized distributor, Iright supplies a wide range of Thermo Fisher choices, technical guidance, and consistent availability to help you match products to your assay and throughput.

    PCR Instruments & Real-Time qPCR Systems (QuantStudio Family)

    Choose between conventional thermal cyclers for endpoint PCR and real-time qPCR systems when you need quantification, melt curves, or genotyping. QuantStudio™ platforms span compact 96-well units to automation-ready 384-well systems, with multiple optical channels and intuitive software for consistent setup, data capture, and reporting across labs.

    For cloning checks and routine screens, use a fast cycling thermal cycler with uniform heating and precise ramp rates. For quantification (gene expression, viral load, CNV), select a QuantStudio real-time system that supports 96/384-well plates, multiplex channels, and reference dyes. If your targets are exceptionally low-abundance or inhibited, consider digital PCR to partition reactions and enable absolute quantification without standard curves.

    PCR Master Mixes & High-Fidelity Enzymes (TaqMan, SYBR)

    Reaction chemistry determines sensitivity, specificity, and speed. Thermo Fisher master mixes are formulated for probe-based or dye-based qPCR, fast cycling, inhibitor resistance, and room-temperature set-up, while high-fidelity polymerases provide superior accuracy for cloning, mutagenesis, and sequencing-bound amplicons.

    How TaqMan Assay Work

    Use TaqMan™ master mixes when you need high specificity, clean multiplexing, and straightforward interpretation. Choose SYBR™ Green mixes when you want cost-effective quantification with melt-curve verification of amplicon identity. For endpoint PCR where error rate matters, pick a proofreading, high-fidelity DNA polymerase to minimize unwanted substitutions and indels.

    How does SYBR Green work?

    TaqMan vs. SYBR at a glance

    Aspect TaqMan™ Probe-Based qPCR SYBR™ Green Dye-Based qPCR
    Specificity Highest (probe + primers) Primer-dependent; verify by melt curve
    Multiplexing Excellent (distinct fluorophores) Limited; spectral bleed-through risk
    Assay Setup Requires probe design No probe; simpler initial setup
    Cost per Reaction Higher Lower

    Reverse Transcription & One-Step RT-qPCR Kits (TaqPath Series)

    RNA assays introduce an extra layer of variability; the right RT workflow reduces hands-on time and improves consistency. Thermo Fisher provides stand-alone reverse transcriptases for two-step RT→qPCR and integrated TaqPath™ one-step RT-qPCR mixes that combine reverse transcription and amplification in a single tube for speed and fewer transfers.

    Choose two-step RT-qPCR when you want to archive cDNA, test multiple targets from the same reverse transcription, or optimize RT and qPCR separately. Choose one-step RT-qPCR for streamlined pathogen detection or high-throughput screening, where reduced handling lowers contamination risk and accelerates time-to-result.

    TaqMan Probes, SYBR Dyes & Reference Standards for qPCR

    Beyond enzymes and buffers, assay-level components stabilize performance. Hydrolysis (TaqMan) probes with non-fluorescent quenchers deliver robust signal-to-noise and multiplexing, while intercalating dyes provide cost-effective fluorescence for single-plex targets and teaching labs. Proper controls—NTC, positive standards, and extraction controls—turn raw fluorescence into defendable decisions.

    Thermo Fisher Taqman PCR

    Include a no-template control to detect contamination, and a positive control or standard curve to confirm chemistry and dynamic range. For consistency across runs, use reference dyes and calibrate optical channels per the instrument manual. When troubleshooting, confirm amplicon identity via melt curve (SYBR) or gel, and check primer/probe design for dimers or SNPs.

    PCR-Grade Plastics: MicroAmp Optical Plates, Adhesive Films, Tubes & 8-Strips

    Thermal transfer and optical clarity depend on the plastics you choose. MicroAmp™ optical plates and films maintain flatness, seal integrity, and high transmittance so qPCR baselines and Ct values remain stable plate-to-plate. Low-binding, RNase/DNase-free tubes and 8-strip formats reduce adsorption losses and improve reproducibility in small volumes.

    Thermo Fisher MicroAmp Optical Plates

    Select 96-well optical plates for routine throughput and 384-well plates when you need more samples per run with less reagent per reaction. Match plate height and skirt style to your instrument’s block, and pair with optical adhesive films or heat seals rated for qPCR. For endpoint PCR, 0.2 mL tubes or 8-strip tubes with domed caps improve condensation management and thermal uniformity.

    Application Kits for Pathogen Detection, Genotyping & Gene Expression

    Assay-specific kits bundle compatible enzymes, buffers, controls, and protocols so you reach validated performance faster. For pathogen detection, one-step RT-qPCR kits streamline viral RNA or bacterial DNA testing with defined targets, controls, and fast cycling options. In genotyping workflows, probe-based assays resolve SNPs and small variants with clear allelic discrimination plots.

    For gene expression, combine reliable reverse transcription with qPCR mixes optimized for low-copy transcripts and reference genes. When you scale up, plate-based formats, premixed controls, and automation-friendly chemistries reduce setup variance and simplify cross-site standardization. Document lot numbers and store kit components at the recommended temperatures to protect sensitivity.

    How to Choose: Match Instrument, Chemistry & Plate Format to Your Assay

    This quick matrix aligns application goals with instrument capacity, chemistry, and plastics. Use it to narrow options, then confirm compatibility with the instrument manual and reagent specifications. If your workflow spans multiple modalities, prioritize the most sensitive step and build around its requirements.

    Application Recommended Instrument Chemistry Plate/Tubes Practical Notes
    Pathogen Detection (RNA) Real-time qPCR (96/384) One-step RT-qPCR, TaqMan™ probes 96-well optical plate + film Include positive/NTC controls; fast cycling compatible
    Low-Copy or Inhibitor-Rich Samples Digital PCR Partition-based absolute quantification Platform-specific consumables Highest sensitivity; no standard curve required
    Gene Expression (mRNA) qPCR (96/384) Two-step RT + TaqMan™ or SYBR™ 384-well for high throughput Normalize with reference genes; verify melt curve for SYBR
    Cloning/Variant Check Thermal cycler (endpoint PCR) High-fidelity polymerase 0.2 mL tubes or 8-strips Confirm by gel or sequencing

    After you identify the row that fits your assay, select master mixes matched to probe or dye chemistry, confirm plate height against your block, and choose seals rated for qPCR optics. If you multiplex, evaluate fluorophore/quencher combinations and spectral compatibility with your instrument’s channels.

    FAQs: Thermo Fisher PCR & qPCR Workflows

    Clear answers reduce setup time and help standardize purchasing. The following points address the questions most teams encounter when moving from pilot to routine runs or scaling across locations with shared methods and reporting.

    Q1. When should I choose TaqMan™ probes over SYBR™ Green?
    Use TaqMan when specificity and multiplexing are priorities, such as genotyping or pathogen panels. Use SYBR for cost-effective single-plex assays where a melt curve confirms amplicon identity. For borderline samples, probe-based assays usually give cleaner thresholds.

    Q2. What happens if my qPCR plate and seal aren’t compatible with the instrument?
    Mismatched plate height or poor-quality optics can shift baselines, flatten amplification curves, and cause edge effects. Always match plate type and seals to instrument guidance, and verify consistent sealing pressure across the plate to prevent evaporation.

    Q3. How do I approach very low-abundance targets or inhibitor-rich matrices?
    Concentrate and clean up nucleic acids, then use inhibitor-tolerant mixes or move to digital PCR. Partitioning increases effective concentration per reaction and bypasses the need for standard curves, improving detection in complex samples.

    Q4. Should I use one-step or two-step RT-qPCR for RNA?
    One-step is faster and reduces handling—ideal for pathogen detection or screening. Two-step is more flexible when you need to archive cDNA or probe many targets from the same reverse transcription. Choose based on throughput and assay breadth.

    Q5. How can I improve reproducibility across sites?
    Standardize master mixes, reference dyes, plate types, and analysis settings. Share validated cycling protocols and templates, lock fluorophore selections, and document lot numbers. Include controls in every run to monitor drift and reagent performance.

    CTA: Get Pricing & Technical Support from Iright

    When you’re ready to build or scale your PCR workflow, Iright can map instrument compatibility, recommend master mixes, and source MicroAmp plates and seals that match your block. You’ll get responsive quotes, batch documentation, and practical tips that keep experiments moving from setup to result.

    • Ask for a compatibility check: instrument model → plate height, seal type, reference dye.

    • Request a tailored short-list: QuantStudio systems, TaqMan/SYBR mixes, and TaqPath one-step kits.

    • Get a fast quote: preferred pack sizes, storage conditions, and delivery options.

    Order Guidelines

    1. Price & Stock Available on Request. Click to send email to: service@iright.com

    2. Please DO NOT make any payment before confirmation.

    3. Minimum order value of $1,000 USD required.

    4. 100% prepayment required.

    Collaboration

    Tony Tang

    Email: Tony.Tang@iright.com

    Mobile/WhatsApp/Wechat: +86-17717886924