Iright
BRAND / VENDOR: Cobetter

Cobetter, L10YYAFBBA1P, Safesure AFB Sterilizing-Grade Bricap L Series Capsule Filters 0.2μm, Gas Filtration

CATALOG NUMBER: L10YYAFBBA1P
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

Check this product with a package size of L10-0.80m² / 9.6 mm (3/8") Hose Barb / Non-sterile(Autoclavable) on Iright. Specifications

Materials
Membrane
Hydrophobic Polytetrafluoroethylene(PTFE)
Support
Polypropylene(PP)
Core/Cage/End Cap
Polypropylene(PP)
Capsule Housing
Polypropylene(PP)
Capsule Vent O-rings
Silicone
Filtration Area
L02-0.16m²L03-0.24m²L05-0.40m²L10-0.80m²L20-1.60m²L30-2.40m²
Operating Conditions
Max. Operating Temperature
80°C
Max. Differential Pressure (Forward)
0.55 MPa @25°C0.10 MPa @80°C

Max. Differential Pressure (Reverse)
0.21 MPa @25°C
Quality Standards
Integrity
100% Integrity testing
Traceability
Each filter with a unique serial number
QMS
ISO 9001:2015
Sterility
Delivery Condition
Non-sterile
Sterilization Method
Can be autoclaved 50 cycles for 30 minutes at 130°C (Can not be steam sterilized in-line)
Package
Pack Size
1/pk
Packaging
Double PE bag
*Note: Cobetter also provides filters with different sterilization methods:
Sterile Breathable Bag Package: Pre-sterilized filters by autoclaved for 30 minutes at 121°C.
Features
PTFE is inherently hydrophobic and further processed for even more hydrophobic, maintaining sterilizing capacity in both unwet and wet condition
Oleo-phobic
High retention rates, low-pressure differential
Use of heat-resistant thickened PP as core, better heat resistance and pressure resistance
Heat resistance, can be steamed in line and autoclaved repeatedly
Applications
Vent filter for fermentation, storage tanks
Sterile filtration for compressed air, oxygen, nitrogen
Single-use system application
Regulatory Compliance
Effluent meets the USP<788> requirement of particulate matter in large volume injection.
Component materials meet the criteria for a “Non-fiber-releasing filter”as defined in 21 CFR 210.3(b)(6).
Retention of 10⁷ cfu/cm² Brevundimonas diminuta(ATCC 19146) according to ASTM F838.
Typical Log Reduction Value (LRV) >7 of Acholeplasma laidlawii (ATCC 23206) according to ASTM F838
Aqueous extraction from a cartridge contains less than 0.25EU/ml as determined by Limulus Amebocyte Lysate (LAL), meeting requirements of USP<85>.
Components meet the requirement of USP <87> In Vitro Biological Reactivity Test.
Components meet the criteria of the USP <88> Biological Reactivity Test for Class V-121 °C plastics.
Components meet the FDA indirect Food Additive requirements cited in 21 CFR177-182.
Based on the current information from our suppliers, all components used in the manufacture of this product are animal-free.
*Contact us for more specification details.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924