Product Description

The pre-assembled and single-use TakeOne® Aseptic Sampling Device allows you to collect perfectly representative samples without any risk from cross contamination, incorrect assembly or ineffective cleaning and sterilization of reusable parts.
Fits to a 25 mm Ingold® Port and provides up to 3 samples. C-Flex® tubing with Quickseal® Disconnect.

TakeOne® solutions are ideal for all in-process sampling requirements in a drug production process.
Quick and Easy Setup
Pre-Assembled
TakeOne® arrives fully assembled and ready for installation to the sampling point.
Eliminate assembly operations where valuable time is lost.
Ready-to-Use
TakeOne® has no spare, reused parts or accessories.
Eliminate the risk of production delays or batch contaminations from lost or damaged parts.
Single-Use
Simply dispose of the TakeOne® device at the end of the batch.
Eliminate the risk of contamination from improper or ineffective cleaning of reusable parts.
Reliable Performance
100% Leak Tested
Each sampling line of every TakeOne® passes a leak-test prior to shipment.
Rely on TakeOne® for dependable and repeatable performance, lot after lot.
Preserve Process and Sample Integrity
The resilient deformable aseptic chamber is at the core of the device.
Bacterial ingress validation demonstrates the chamber form a microbial barrier after actuation.
As verified by statistical analysis, the aseptic chamber returns to a like-new condition after 40 actuations and 10 SIP cycles after actuation.
Robust Design for Operator and Process Safety
316L Stainless Steel Faceplate
Careful selection of the materials of construction make the TakeOne® sampling device engineered to perform.
The sanitary fitting complies with ASME-BPE standards to ensure a correct and secure fit to process equipment.
Trust the 316L stainless steel fitting of TakeOne® to perform as you would any fitting, even during aggressive SIP conditions.
Spring-Return Actuator
An internal spring automatically retracts the needle back into the device after sampling.
This feature affords protection from exposure to sharps and encourages sample volume control.
Pre Designed Solutions for Every Process Area
In-process sampling is a requirement at each process step to ensure a drug products' safety, identity, strength, purity and quality. Yet there are some differences in the sampling requirements between Process Areas. Leveraging our expertise gained from helping our customers succesfully take hundreds of thousands of aseptic samples, Sartorius presents a family of Pre Designed Solutions that meet the general sampling requirements of each process area.
Cell Culture and Downstream Intermediates
Check for sterility, bioburden and non-host organisms prior to and just after inoculation, after recovery and hold steps and at batch conclusion
Regular checks cell count, viability, density and other critical process parameters
Buffer and Media Preparation
Check for sterility prior to and after additions or transfers
Check for endotoxin prior to and after additions or transfers
Regular checks of pH, titration, conductivity, concentrations and other critical process parameters
Drug Substance Purification
Check for bioburden prior to 0.2µm filtration, during equipment calibration, after any additions and at end of process
Check for endotoxin during equipment calibration, after any additionss, at end of end of process, after chomatography steps and at end of end of process
Regular checks of osmolality, viral|protein concetration, pH and other critical process parameters
Drug Product Formulation
Check for bioburden prior to 0.2µm filtration, prior to fill and finish, after filling, at end of hold time and at end of process
Check for endotoxin prior to fill and finish, after filling, at end of hold time and at end of process
Regular checks of osmolality, viral|protein concetration, pH and other critical process parameters

Specifications
Applications:
Application Area: Aseptic sampling
Process Step: Cell Harvest & Downstream Processing Intermediates; Media Preparation; Buffer Preparation; Drug Substance Purification; Drug Product Formulation

Connections (Physical):
Connector(s): 25 mm Ingold® Port
Sampling Lines: 3

General Specifications:
Tubing: TPE (Tuflux® TPE)

Materials of Construction:
Tubing Material: Synthetic Thermoplastic Elastomer

Product Information:
Brand: TakeOne®
Container Format: Bag
Container Type: 3 × 250 mL Flexsafe® bag manifold

Sterility/Purity:
Delivery Condition: Sterile
Sterilization Method: Gamma irradiation

Volume:
Capacity: 3 total samples

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)