Iright
BRAND / VENDOR: Waters

Waters, 186003010, XBridge BEH Shield RP18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pk

CATALOG NUMBER: 186003010
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 2 pH
pH Range Max: 11 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Bonding Technology: Shield RP18
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 5 µm
Endfitting Type: Waters
Pore Size: 130 Å
Format: Column
Surface Area: 185
System: HPLC
Particle Technology: BEH
USP Classification: L1
Inner Diameter: 4.6 mm
Length: 250 mm
Carbon Load: 17 %
UNSPSC: 41115709
Brand: XBridge
Product Type: Columns
Units per Package: 1 pk

Additional Information
XBridge BEH Shield RP18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pk Optimize the test conditions that are imperative to achieving a successful separation using the XBridge BEH Shield RP18 Columns. Having the ability to successfully operate over a wide range of pH with a variety of solvents, the XBridge BEH Shield RP18 Columns offer an alternate selectivity. Achieve superior separation of bases with the XBridge BEH Shield RP18 Columns. Reduced silanol interactions with basic analytes are observed with the XBridge BEH Shield RP18 Columns, which utilize the patented Shield Technology, and achieve highly symmetrical and efficient peaks. This deactivation of basic analytes is the ‘Shielding’ effect that results in improved peak shape. This is far superior than the ordinary C18 columns available in the market that give poor peak symmetry due to secondary interactions with basic compounds due to weak cation exchange with residual surface silanols. Use less time and greater confidence in developing robust separations to fully utilize the power of pH with the XBridge BEH Shield RP18 Columns. You may also be interested in other lab equipment such as the XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 1 mm X 50 mm, 1/pk similar to the product listed here but suitable for analytes with particle size 3.5 µm. Shop for lab equipment and see the complete available range of Waters Xbridge BEH Shield Columns, and browse through other suitable lab equipment as well.

FAQ
What Is The Difference Between C8 And C18 Columns In HPLC? Both the C8 and C18 are two types of straight-chain alkyl groups used in the reverse-phase chromatography of HPLC for the surface modification of silica. The reverse-phase chromatography uses an aqueous, moderately polar mobile phase.

The fundamental difference between C8 and C18 columns used in HPLC is that the stationary phase of the C8 columns contain octyl carbon chain (C8)-bonded silica, but the C18 column contains octadecyl carbon chain (C18)-bonded silica. In addition to this, the C8 columns are less hydrophobic, and have less density, while the C18 columns are more hydrophobic and have a higher density. For this reason, the C8 columns exhibit a low retention time, while the C18 columns have a higher retention time. And thus, lower separation is achieved with the C8 columns, but the C18 columns give a higher separation.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924