Product Description
Mass Spectrometry (SQD) standards kit for system assessment. 6 Components: 1. 1 x 10 mL Set-up Solution QP: PPG 1000 2.5ng/uL, triacetyl-B-cyclodextrin 5.0 ng/uL, verapamil 100.0 pg/uL, ammonium acetate 0.31mg/mL, Leucine Enkaphalin 1ng/ul; all in Acetonitrile/Water (1:1 V/V) 2. 1 x 10 mL Stock Solution: Reserpine 1ng/uL, Chloramphenicol 2ng/uL, in Acetonitrile/Water (1:1 V/V) 3. 1 x 10 mL Tuning Solution : Reserpine 100 pg/ul, Chloramphenicol 200 pg/ul Acetonitrile/Water (1:1 V/V) 4. 2 x 10 mL Working Solution Reserpine 10 pg/ul +1% - 0% Chloramphenicol 20 pg/ul +1% - 0% Acetonitrile/Water (1:1 V/V) 5. 1 x 10 mL API Calibration Solution Sodium Iodide 2 ug/ul +1% - 0% Cesium Iodide 50 ng/ul +1% - 0% IPA/Water (1:1 V/V) 6. 1 x 10 mL Mobil Phase Blank Acetonitrile/Water 50/50 Acetonitrile/Water (1:1 V/V) Certificate of Analysis *Each Stock, (2, 3, 4) Tuning and Working Solution packaged in brown nalgene bottles *Set-up solution (1) packaged in brown nalgene bottle * Calibration solution (5) packaged in clear nalgene bottle * Mobil Phase Blank solution (6) packaged in clear nalgene bottle
Specifications
Separation Mode: Reversed Phase
Detection Method: MS
Formulation: Liquid
Storage Condition: Room Temperature
System Type: MS
Shelf Life: 12 Months
Shipping Condition: Ambient
Type: Reference
UNSPSC: 41116107
Application: System Performance
Product Type: Standards
Units per Package: 1 pk
Additional Information
SQD Standards Kit The Mass Spectrometry SQD Standards Kit for system assessment comprises of 6 components. The components are 1. [1 x 10 mL] Set-up Solution QP: PPG 1000 2.5ng/uL, triacetyl-B-cyclodextrin 5.0 ng/uL, verapamil 100.0 pg/uL, ammonium acetate 0.31mg/mL, Leucine Enkaphalin 1ng/ul; all in Acetonitrile/Water (1:1 V/V). 2. [1 x 10 mL] Stock Solution: Reserpine 1ng/uL, Chloramphenicol 2ng/uL, in Acetonitrile/Water (1:1 V/V). 3. [1 x 10 mL] Tuning Solution: Reserpine 100 pg/ul, Chloramphenicol 200 pg/ul Acetonitrile/Water (1:1 V/V). 4. [2 x 10 mL] Working Solution Reserpine 10 pg/ul +1% - 0% Chloramphenicol 20 pg/ul +1% - 0% Acetonitrile/Water (1:1 V/V). 5. [1 x 10 mL] API Calibration Solution Sodium Iodide 2 ug/ul +1% - 0% Cesium Iodide 50 ng/ul +1% - 0% IPA/Water (1:1 V/V). 6. [1 x 10 mL] Mobil Phase Blank Acetonitrile/Water 50/50 Acetonitrile/Water (1:1 V/V). The Mass Spectrometry SQD Standards Kit is shipped with a Certificate of Analysis; each Stock, (2, 3, 4) Tuning and Working Solution packaged in brown Nalgene bottles; Set-up solution (1) packaged in a brown Nalgene bottle; Calibration solution (5) packaged in a clear Nalgene bottle, and the Mobile Phase Blank solution (6) packaged in a clear Nalgene bottle. This product contains hazardous materials that necessitate specific shipping procedures. Direct physical contact should be avoided because all substances should be regarded as harmful. Make sure there is enough ventilation to keep airborne levels below the minimum exposure limits. Use safety equipment that has been approved by MSHA and the National Institute for Occupational Safety and Health. To avoid contact with eyes, skin, and clothing, wear chemical goggles, face shields, gloves, and chemical-resistant clothing, such as a laboratory coat and/or a rubber apron. The SQD Standards Kit should be kept at a temperature of less than 4° C. Keep in a firmly sealed container in a corrosion-proof location. Only people who have been educated in the safe handling of hazardous materials should use this product. Browse through our brochure or our website to attain the full list of Waters offerings, and shop for lab equipment to meet your laboratory demands. You may also be interested in checking out the LCMS QC Reference Material; Acetaminophen, Caffeine, Sulfaguanidine, Sulfadimethoxine, Val,-Tyr-Val, Verapamil, Terfenadine, Leucine-Enkephalin, and Reserpine are among the nine components of the LCMS QC Reference Material, which is packaged in a Waters vial. This standard is a comprehensive reference for LC/MS or MS apparatus in a wide range of circumstances and procedures.
FAQ
What Is The Expected Shelf Life Of The Mass Spectrometry SQD Standards Kit? If stored and handled adequately, the Mass Spectrometry SQD Standards Kit is expected to have a shelf life of 12 months.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmation.
3. Minimum order value of $1,000 USD required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924