BRAND / VENDOR: BD
BD, 552932, BD™ Cytometric Bead Array (CBA) Human Inflammatory Cytokine Lyophilized Standard
CATALOG NUMBER: 552932
- quedan 99 artículos
- Pedido pendiente, envío pronto
No reviews
CATALOG NUMBER: 552932
Preparation And Storage: Preparation And Storage Store the lyophilized standard at 4°C prior to reconstitution. Lyospheres from 1 vial of the Human Inflammatory Cytokine Standard, when reconstituted in 2.0 mL Assay Diluent, approximates the CBA activity of human Interleukin (IL)-8, IL-1β, IL-6, IL-10, Tumor Necrosis Factor (TNF), and IL-12p70 at a concentration of 5000 pg/mL. Following reconstitution, maintain the Human Inflammatory Cytokine Standard at 4°C and use within 12 hours. Any unused reconstituted standard must be discarded after this period (do not store or reuse).
Recommended Assay Procedures: Recommended Assay Procedures The Human Inflammatory Cytokine Standard has been tested with the BD™ CBA Human Inflammatory Cytokine Kit (Cat. No. 551811) to assure protein amounts and function in the BD™ CBA assay. Investigators are encouraged to refer to the CBA kit manual or to the abbreviated instruction below (Preparation of Human Inflammatory Cytokine Standard Protocol). The Human Inflammatory Cytokine Standard should be reconstituted using Assay Diluent supplied with the aforementioned CBA kits (component no. 51-2432KC) or it may be purchased separately (Cat. No. 560104). Preparation of Human Inflammatory Cytokine Standard : The Human Inflammatory Cytokine Standard is lyophilized and should be reconstituted and serially diluted before mixing with CBA capture beads and PE detection reagents. 1. Open one vial of the lyophilized Human Inflammatory Cytokine Standard. Transfer all the lyospheres to a polypropylene tube (BD Falcon™, Cat. No. 352097). Label the tube "Top Standard". 2. Reconstitute the standard with 2.0 mL of Assay Diluent. Allow the reconstituted standard to equilibrate for at least 15 minutes before making dilutions. Mix the reconstituted protein by pipette only. Do not vortex or mix vigorously. 3. Label additional 12 x 75 mm tubes (BD Falcon™, Cat. No. 352008) and arrange them in the following order: Top Standard, 1:2, 1:4, 1:8, 1:16, 1:32, 1:64, 1:128, and 1:256. 4. Add 300 µl of Assay Diluent to each of the dilution tubes. 5. Perform a serial dilution by transferring 300 µl from the Top Standard to the 1:2 dilution tube and mix thoroughly. Do not vortex, mix by pipet only. Continue making serial dilutions by transferring 300 µl from the 1:2 tube to the 1:4 tube and so on to the 1:256 tube and mix thoroughly. Prepare one tube containing only Assay Diluent to serve as the 0 pg/mL negative control.
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmtaion.
3. Minimum order value of $1,000 USD required.
4. 100% prepayment required.
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924