BRAND / VENDOR: BD

BD Pharmingen™ PerCP-Cy™5.5 Mouse Anti-Human CD39 564899

CATALOG NUMBER: 564899

Precio habitual$0.99
/
Los gastos de envío se calculan en la pantalla de pagos.
  • quedan 99 artículos
  • Pedido pendiente, envío pronto

Este sitio está protegido por hCaptcha y se aplican la Política de privacidad de hCaptcha y los Términos del servicio.

Product Description

Alternative Name: ENTPD1; NTPDase-1; Ecto-ATPase 1; Ecto-ATPDase 1
Reactivity: Human (QC Testing)
Isotype: Mouse IgG2b, κ
Application: Flow cytometry (Routinely Tested)
Vol. Per Test: 5 µl
Workshop Number: IV A54
RRID: AB_2739005
Storage Buffer: Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
Regulatory Status: RUO
Preparation And Storage: Preparation And Storage Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with PerCP-Cy5.5 under optimum conditions, and unconjugated antibody and free PerCP-Cy5.5 were removed. Storage of PerCP-Cy5.5 conjugates in unoptimized diluent is not recommended and may result in loss of signal intensity.
Product Notices: Product Notices This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test). An isotype control should be used at the same concentration as the antibody of interest. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing. Source of all serum proteins is from USDA inspected abattoirs located in the United States. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination. PerCP-Cy5.5–labelled antibodies can be used with FITC- and R-PE–labelled reagents in single-laser flow cytometers with no significant spectral overlap of PerCP-Cy5.5, FITC, and R-PE fluorescence. PerCP-Cy5.5 is optimized for use with a single argon ion laser emitting 488-nm light. Because of the broad absorption spectrum of the tandem fluorochrome, extra care must be taken when using dual-laser cytometers, which may directly excite both PerCP and Cy5.5™. We recommend the use of cross-beam compensation during data acquisition or software compensation during data analysis. CF™ is a trademark of Biotium, Inc. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors. Cy is a trademark of GE Healthcare. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924