BRAND / VENDOR: Waters
Waters, 186008979, XBridge Peptide BEH C18 XP Column, 130 Å, 2.5 µm, 2.1 mm X 50 mm, 1/pk
CATALOG NUMBER: 186008979
- quedan 99 artículos
- Pedido pendiente, envío pronto
No reviews
CATALOG NUMBER: 186008979
The XBridge Peptide BEH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm columns are optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed for proteomic, peptide mapping, and synthetic peptide applications. 2.1mm ID columns are recommended for use with low dispersion (UPLC or UHPLC) systems, especially for LC-MS methods. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c (p/n: 186006371) to before being QC accepted as a Peptide separation column. Suggested Use: Peptide Separations, Peptide Analysis
Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Temperature Limits: 90 C
Maximum Pressure: 18000 psi (1240 Bar)
Particle Size: 2.5 µm
Pore Size: 130 Å
QC Tested: Peptide
Format: Column
System: UPLC, UHPLC
Particle Technology: BEH
USP Classification: L1
Inner Diameter: 2.1 mm
Length: 50 mm
UNSPSC: 41115709
Application: Peptide
Brand: XBridge
Product Type: Columns
Units per Package: 1 pk
Additional Information
XBridge Peptide BEH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pk With the XBridge Peptide BEH C18 XP Column, you can assess samples for proteomics over a wide pH range with low pH stability and ultra-low column bleed. Protein characterization and peptide synthesis are also possible with the lab equipment's small-pore (130Å) trifunctionally bound BEH particle. For peptide separations, the XBridge Peptide BEH C18 XP Column uses Peptide Separation Technology (PST) and the lab equipment has been optimized and QC verified. The 2.5 μm eXtended Performance [XP] columns, packed in ultra-low dispersion hardware, provide superior separation performance, resilience, and throughput for HPLC tests while allowing for a smooth transition to UPLC adoption. Add the XBridge Peptide BEH C18 XP Column to your lab equipment inventory to take advantage of the Protein Separation Technology of the analytical column, which integrates BEH technology and uses synthetic particles to provide the best quality and consistent performance. The packing materials for the XBridge Peptide BEH C18 XP columns were created in a cGMP, ISO 9002 accredited plant utilizing an ultra-pure reagent to give good peak shape, high efficiency, and outstanding stability. A peptide separation is performed on each batch of XBridge Peptide BEH C18 Column material, and the results are held to limited specification ranges. This is done to provide high, repeatable peptide separation performance. Every lab equipment is tested, and a Performance Test Chromatogram is included in the box with each column, along with a Certificate of Acceptance. To assure the stability of peptide separation processes, the XBridge Peptide BEH C18 XP Column is QC verified with a peptide map. This is made possible by applying well-known, cutting-edge bonding processes for the C18 ligand, which offer consistent results across a wide range of samples used in proteomics, protein characterization, and peptide synthesis. As a result, you may rely on the analytical column's consistency and obtain reliable synthetic peptide and protein digest separations from batch to batch. The processes utilized in the lab equipment's fabrication ensure that particle structure and bonding chemistry are stable across a wide working pH range and at high temperatures. Invest in the XBridge Peptide BEH C18 VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk so you can protect your analytical lab equipment from harm.
FAQ
What pH Limit Is Offered By The XBridge Peptide BEH C18 XP Column? The XBridge Peptide BEH C18 XP Column listed here can work well with a pH range of 1 to 12.
1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmation.
3. Minimum order value of $1,000 USD required.
Tony Tang
📧Email: Tony.Tang@iright.com
📱Mobile/WhatsApp/Wechat: +86-17717886924