Iright
BRAND / VENDOR: Biolegend

Biolegend, 353427, Purified anti-human CD196 (CCR6) (Maxpar® Ready) Antibody, 100μg

CATALOG NUMBER: 353427
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

CCR6, also known as CD196, is a chemokine receptor that is expressed on immature dendritic cells, B lymphocytes, and memory T cells. CCR6 binds CCL20, although members of the β defensin family also bind CCR6 with a lower affinity. CCR6 positive cells, and its ligand CCL20, have been detected in numerous organs, especially the secondary lymphoid organ. CCL20 is selectively made by the follicle-associated epithelium (FAE) overlying Peyers Patches (PPs) and isolated lymphoid follicles (ILFs). CCL20 contributes to the recruitment of CCR6-expressing B cells to these structures. In humans, CCR6 can function to mediate arrest of T cells on dermal endothelial cells and is highly expressed on T cells resident in both normal and psoriatic skin. CCR6 and/or CCL20 have been implicated in the pathogenesis of rheumatoid arthritis and inflammatory bowel disease. Human T cells that are able to produce IL-17 express CCR6. It suggests that CCL20 and CCR6 have a role in inflammatory diseases by recruiting Th17 cells to target tissues.
100μg
Verified Reactivity: Human, Cynomolgus, Rhesus
Reported Reactivity: African Green, Baboon
Antibody Type: Monoclonal
Host Species: Mouse
Immunogen: CCR6-transfected cells
Formulation: Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and EDTA.
Preparation: The antibody was purified by affinity chromatography.
Concentration: 1.0 mg/ml
Storage & Handling: The antibody solution should be stored undiluted between 2°C and 8°C.
Application: FC - Quality tested CyTOF® - Verified
Recommended Usage: This product is suitable for use with the Maxpar® Metal Labeling Kits. For metal labeling using Maxpar® Ready antibodies, proceed directly to the step to Partially Reduce the Antibody by adding 100 µl of Maxpar® Ready antibody to 100 µl of 4 mM TCEP-R in a 50 kDa filter and continue with the protocol. Always refer to the latest version of Maxpar® User Guide when conjugating Maxpar® Ready antibodies.
Additional Product Notes: Maxpar® is a registered trademark of Standard BioTools Inc.
Product Citations: Stras SF, et al. 2020. Developmental Cell. 51(3):357-373.e5.. PubMed Wei SC et al. 2017. Cell. 170(6):1120-1133 . PubMed Roussel M, et al. 2021. Cell Reports Medicine. 2(6):100291. PubMed Jordan S, et al. 2020. Cell. 178(5):1102-1114.e17.. PubMed
RRID: AB_2563725 (BioLegend Cat. No. 353427)
Structure: Chemokine receptor, GPCR, seven transmembrane receptor
Distribution: Immature dendritic cells, B lymphocytes, memory T cells, Th17 cells
Function: Host defense, important for recruitment of B cells to secondary lymphoid organs, mediates arrest of T cells on dermal endothelial cells
Ligand/Receptor: CCL20 (MIP-3α)
Cell Type: B cells, Dendritic cells, T cells, Th17
Biology Area: Immunology
Molecular Family: CD Molecules, Cytokine/Chemokine Receptors, GPCR
Antigen References: 1. Zaballos A, et al. 1996. Biochem. Bioph. Res. Co. 227:846. 2. Yang D, et al. 1999. Science 286:525. 3. MacDonald KG, et al. 2007. Am. J. Pathol. 170:1229. 4. Homey B, et al. 2000. J. Immunol. 164:6621. 5. Hirota K, et al. 2007. J. Exp. Med. 204:2803. 6. Singh SP, et al. 2008. J. Immunol. 180:214.
Gene ID: 1235
UniProt: View information about CD196 on UniProt.org
Clone: G034E3
Regulatory Status: RUO
Other Names: BN-1, CKR6, DCR2, CKRL3, DRY-6, GPR29, CKR-L3, CMKBR6, GPRCY4, STRL22, GPR-CY4
Isotype: Mouse IgG2b, κ
Q: Does staining at room temperature or even at 37°C help for checking chemokine receptors expression?
A: Due to continuous recycling of many chemokine receptors, it may be worthwhile to consider staining at room temperature or at 37°C if the staining at lower temperature (which can potentially reduce receptor turnover) is not optimal.
Q: Can I obtain CyTOF data related to your Maxpar® Ready antibody clones?
A: We do not test our antibodies by mass cytometry or on a CyTOF machine in-house. The data displayed on our website is provided by Fluidigm®. Please contact Fluidigm® directly for additional data and further details.

http://techsupport.fluidigm.com/
Q: Can I use Maxpar® Ready format clones for flow cytometry staining?
A: We have not tested the Maxpar® Ready antibodies formulated in solution containing EDTA for flow cytometry staining. While it is likely that this will work in majority of the situations, it is best to use the non-EDTA formulated version of the same clone for flow cytometry testing. The presence of EDTA in some situations might negatively affect staining.
Q: I am having difficulty observing a signal after conjugating a metal tag to your Maxpar® antibody. Please help troubleshoot.
A: We only supply the antibody and not test that in house. Please contact Fluidigm® directly for troubleshooting advice: http://techsupport.fluidigm.com/
Q: Is there a difference between buffer formulations related to Maxpar® Ready and purified format antibodies?
A: The Maxpar® Ready format antibody clones are formulated in Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and EDTA. The regular purified format clones are formulated in solution that does not contain any EDTA. Both formulations are however without any extra carrier proteins.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924