BRAND / VENDOR: Cobetter

Cobetter, ASHBB207SP, Safesatable SHB Sterilizing-Grade Filter Cartridge 0.2μm

CATALOG NUMBER: ASHBB207SP
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

Check this product with a package size of A-Standard Cartridge / 0.2μm / 20 inch on Iright. Specifications

Materials
Membrane
Hydrophilic Polytetrafluoroethylene (PTFE)
Support
Polypropylene(PP)
Core/Cage/End Cap
Polypropylene(PP)
Cartridge End Cap Inserts
Polybutylene terephthalate (PBT)
Cartrdige End Cap O-rings
Silicone/EPDM/Fluoroelastomer/PFA encapsulated O-rings
Pore Size
Single-layer 0.2 μm
Filtration Area
A-Standard Cartridge (10")-0.56m²
Operating Conditions
Max. Operating Temperature
80°C
Max. Differential Pressure (Forward)
A-Standard Cartridge:0.69 MPa @ 25°C0.40 MPa @ 60°C0.24 MPa @ 80°C
Max. Differential Pressure (Reverse)
0.30 MPa @25°C0.10 MPa @ 80°C
Sterilization Option
A-Standard Cartridge
Can be steam sterilized for 30 minutes at 135 °C with 35 cycles (< 30 kPa);Can be autoclaved 35 cycles for 30 minutes at 130°C
Quality Standards
Integrity
100% Integrity testing
Traceability
Each filter with a unique serial number
QMS
ISO 9001:2015
Package
Pack Size
1/pk
Packaging
Double PE bag

Features
Great chemical compatibility
Hydrophilic PTFE membrane
Applications
Sterile Filtration of organic compounds
Filtration of disinfectant
Filtration of strong acid and alkali
High temperature filtration
Regulatory Compliance
Effluent meets the USP<788> requirement of particulate matter in large volume injection.
Component materials meet the criteria for a “Non-fiber-releasing filter”as defined in 21 CFR 210.3(b)(6).
Retention of 10⁷ cfu/cm² Brevundimonas diminuta(ATCC 19146) according to ASTM F838.
Aqueous extraction from a cartridge contains less than 0.25EU/ml as determined by Limulus Amebocyte Lysate (LAL), meeting requirements of USP<85>.
Components meet the requirement of USP <87> In Vitro Biological Reactivity Test.
Components meet the criteria of the USP <88> Biological Reactivity Test for Class V-121 °C plastics.
Components meet the FDA indirect Food Additive requirements cited in 21 CFR177-182.
Based on the current information from our suppliers, all components used in the manufacture of this product are animal-free.
*Contact us for more specification details.