Product Description
Check this product with a package size of 1/2"-1/2" HB / Non-sterile / 10/pk on Iright. Cobetter Lifemeta SF single-use check valve is mainly used to control the direction of fluid flow. The diaphragm sealing design effectively prevents fluid backflow, reducing the risk of material contamination.
In the non-working state, the diaphragm of the check valve is in the closed state. Its two ports use a hose barb design, which is convenient to connect tubing and realize liquid transfer.
Specifications
Brand
Accessory Brand
Lifemeta™ SF Single-Use Check Valve
Physical Properties
Material
Polypropylene(PP)+Silicone
Biological Safety
Bacterial Endotoxin
<0.25 EU/ml
Sterilization Option
Gamma-irradiation
25-45 kGy
Autoclave(130°C)
1 cycle, 30 mins
Package
Delivery Condition
Non-sterile/Sterile Individually Packed
Pack Size
10 pcs/pk
Features
Polypropylene main body with silicone septum
The diaphragm opening pressure is low, basically 0 kPa
Ensure directional flow of liquid and prevent backflow
Polypropylene and silicone material, with a maximum pressure resistance of 5 bar
Alleviate the problem of air trapping
Regulatory Compliance
ISO™ 9001:2015 Quality management system
ADCF raw materials, manufacturing in the ISO Class 7 clean zones
Resin raw material meets the requirement of USP <87> in Vitro Biological Reactivity Test
Resin raw material meets the requirement of USP <88> Biological Reactivity Test, in Vivo for Class VI plastics
Particulate matter in the product eluent meets the requirement in USP <788> for large volume parenterals Q: The material of the film-coated tee pressure gauge?
The film-coated tee pressure gauge does not require a gasket and is made of HDPE+KA film. It cannot withstand steam sterilization.
Q: Will a single-use system that has been irradiated have any impact on the product? Can irradiation residues be detected in the irradiated items?
No. The irradiation dose is validated to ensure sterilization effectiveness. Moreover, the irradiation process only involves energy absorption and does not involve direct contact with the radiation source. Therefore, there are no issues of irradiation residues in the disposable system.
Q: The clamp does not tighten or fit. What should I do?
This may be due to the thickness of the TC connector. It is recommended to use Cobetter's clamp with Cobetter's TC flange.