Product Description
Check this product with a package size of 25mm / 0.45μm / 100pcs/pk on Iright. Cobetter Nylon syringe filters are made of naturally hydrophilic Nylon66 membrane and are widely used for clarification or particle removal under non-sterile conditions and compatible with a broad range of solvents including aqueous and organic solutions. They are the economical and popular choice for filtering most general laboratory solutions.
Specifications
Connections
Inlet
Female Luer Lock
Outlet
Male Luer Slip
Materials
Housing
PP
Membrane
Nylon
Wettability
Hydrophilic
Physical Properties
Pore Size
0.22 μm, 0.45 μm, 0.8 μm
Filter Diameter
13mm
25mm
33mm
Filtration Area
0.72cm²
3.4cm²
4.5cm²
Maximum Operating Pressure
6bar
3bar
2bar
pH Range
3.0 – 14.0
Sterility
Delivery Condition
Nonsterile
Sterilization Method
Not Recommended
Package
Pack Size
100pcs
Packaging
Bulk packed
Performance
Filter Diameter
Pore Size
Flow Rate (mL/min@0.21Mpa,20°C, 210kPa, 30psi)
Bubble Point(MPa, Water)
13mm
0.22μm
15
≥0.3
0.45μm
27
≥0.2
0.8μm
183
≥0.04
25mm
0.22μm
78
≥0.3
0.45μm
138
≥0.2
0.8μm
693
≥0.04
33mm
0.22μm
121
≥0.3
0.45μm
110
≥0.2
0.8μm
775
≥0.04
Features
Compatible with both aqueous(non-acidic) and organic solutions
Broad chemical compatibility and flexibility
Low extractables or leachables
High protein binding
High mechanical stability
High dirt loading capacity
HPLC, GC, or dissolution sample analysis
Applications
Clarification or sterilization of aqueous and organic solutions
Filtration of mixed solvents and solvents
General sample preparation
Clarification or particle removal before HPLC analysis
Select by Volume
Sample Volume
Filter Diameter
Filtration Area
Hold-up Volume
< 10mL
13mm
0.72 cm²
< 25μl
10mL to 100mL
25mm
3.4 cm²
< 100μl
100mL to 200mL
33mm
4.5 cm²
< 125μl
How to use a syringe filter?
Choose the right type of membrane material based on the properties of your sample. Be careful of the chemical compatibility to avoid extractables and leachables. Read this article about How to choose a syringe filter.
1. Load the sample into the syringe.
2. Attach the filter to the luer-lock of the syringe with a twisting motion. Make sure it is securely attached.
3. Filter the sample. Hold the syringe and filter vertically, and gently press the plunger to push the sample through the filter. Take care not to apply too much force or you may damage the filter.
4. Discard the used filter and repeat for the next sample.