Check this product with a package size of 1"(25.4mm) ID x 1-3/8"(34.9mm) OD x Wall 4.8mm - 92# / 5 m / With Logo Printing on Iright. Cobetter Lifemeta™ STF TPE tubing is a high-performance flexible tube extruded from medical-grade thermoplastic elastomer (TPE) material, with excellent heat sealing and sterile welding performance. Its inner wall is smooth and low-flaking. The Lifemeta™ STF has demonstrated considerable welding compatibility and weldability in comparison to the leading TPE tubes in the market. Compared with traditional silicone and PVC tubes, this product has wide chemical compatibility and can maintain excellent physicochemical performance under various working conditions.
Specifications
Brand
Tubing Brand
Lifemeta™ STF
Physical Properties
Color
Translucent
Material
Thermoplastic Elastomer(TPE)
Length
15m(50ft)
Durometer Hardness (Shore A)
60 ± 5
Burst Strength
0.4 - 0.6 MPa
Tensile Strength
5.17-5.18 MPa
Elongation at Break
742-776 %
Vacuum Resistance
>30 kPa
Temperature Range
-50 °C to 140 °C
Biological Safety
Endotoxins
<0.25 EU/ml
Bio-compatibility
Meet the requirement of USP<87> In Vitro Cytotoxicity Test;Meet the criteria of the USP<88> Biological Reactivity Test for Class VI-121°C plastics
Sterilization Option
Gamma-irradiation
25-45 kGy in a sterile package and can not be re-sterilized.
Autoclave(121°C)
25 cycles, 30min
Package
Pack Size
1/pk
Delivery Condition
Nonsterile
Packaging
Coil packaged in double PE bag
Features
Sterile welding and heat sealing
Excellent low absorption and low binding
Lower permeability compared to silicone resin
Smooth inner wall, excellent fluidity
Outstanding tensile strength
Applications
Cell culture media and buffer preparation
Liquid sampling systems
Filtration processes
Sterile filling
Sterile disconnect and connection
Single-use tubing assemblies
Regulatory Compliance
Aqueous extraction contains < 0.25 EU/mL as determined by Amebocyte Lysate, USP <85>.
Meet the requirement of USP <87> In Vitro Biological Reactivity Test.
Meet the criteria of the USP <88> Biological Reactivity Test for Class VI plastics.
Products do not contain animal derived components and are free from TSE risk.
These products are manufactured in a facility which adheres to ISO™ 9001:2015 Practices.
Related Articles
1. Applications of Cobetter Lifemeta™ STF TPE Tubing Q: What's the application of STS platinum-cured silicone tubing?
Cobetter STS platinum-cured silicone tubing is designed to facilitate fluid transfer in many pharmaceutical and biopharmaceutical applications.
Q: How many internal diameters are available for platinum-cured tubings?
Cobetter STS platinum-cured silicone tubing is available in 7 different internal diameters ranging from 1/8" (3mm) to 3/4" (19mm).
Q: What's the sterility method?
Gamma irradiation and autoclave.
Q: Cobetter’s custom tubing assemblies are non-sterile, can customers sterilize it by themselves?
1. Yes, customers can sterilize only the tubing assemblies and the connectors, excluding any bags.
2. When customers sterilize the connectors and tubing, all ports should be opened, such as connector plugs and blind caps on clamps. After sterilization is completed, they can be connected and used.
3. Especially attention shall be taken that you will need to add an additional cable tie to offset the leakage risk caused by the high-temperature deformation of the original cable tie after off-line sterilization.
Q: What is the recommended length to be reserved for thermoplastic tubing for aseptic connection and aseptic sealing?
Cobetter's aseptic connection machine and aseptic sealing machine can achieve aseptic connection and disconnection in general environments. It is recommended to reserve a length of 15cm for each connection and disconnection.
Q: Can silicone tubing and pump tubing be used for organic solvent solutions?
Silicone tubing is not resistant to organic solvents.
For pump tubing, we need to confirm specific details of the process, such as pipe diameter, operating pressure, duration of use, and the acidity/alkalinity of the fluid being pumped. If organic solvents are involved, it is recommended not to choose silicone tubing and instead opt for pump tubing that is resistant to organic solvents.
Q: Will a single-use system that has been irradiated have any impact on the product? Can irradiation residues be detected in the irradiated items?
No. The irradiation dose is validated to ensure sterilization effectiveness. Moreover, the irradiation process only involves energy absorption and does not involve direct contact with the radiation source. Therefore, there are no issues of irradiation residues in the disposable system.
Q: Are the integrity testing of bags and tubings conducted together?
The pressure resistance of the bags and tubings is different. The bag can withstand a pressure of 0.02 kg. For the bag, we apply a gas pressure of around 0.015 bar or 0.02 bar after clamping with bag clamps. After a certain period, we measure the pressure decay. The tubing and fittings can withstand pressure of up to approximately 2 bar, and we apply a pressure of 1.6 or 1.7 bar to measure the pressure decay.
Q: How do the drawings correspond to the product packaging?
Each product shown on a drawing represents the product within one package. If separate packaging or simultaneous use of multiple products is required, they can be split/integrated into a single drawing.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmation.
3. Minimum order value of $1,000 USD required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924