Waters, 186000456, XTerra Shield RP18 Column, 125Å, 5 µm, 2.1 mm X 150 mm, 1/pk

CATALOG NUMBER: 186000456

Regular price$0.99
/
Shipping calculated at checkout.
  • 99 items in stock
  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 2 pH
pH Range Max: 12 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Bonding Technology: Shield RP18
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 5 µm
Endfitting Type: Waters
Pore Size: 125 Å
Format: Column
Surface Area: 175
System: HPLC
USP Classification: L1
Inner Diameter: 2.1 mm
Length: 150 mm
Carbon Load: 15 %
UNSPSC: 41115709
Brand: XTerra
Product Type: Columns
Units per Package: 1 pk

Additional Information
XTerra Shield RP18 Column, 125Å, 5 µm, 2.1 mm X 150 mm, 1/pk By utilizing the XTerra Shield RP18 Column, you can get around some of the main limitations of the silica-based reversed-phase packing materials, particularly their hydrolytic instability at high pH. The lab equipment takes use of the proprietary organic/inorganic hybrid particle technology (HPT) from Waters, which enables it to provide considerable advantages over conventional silica columns. The first commercially viable substitute for silica-based column technology is the Waters XTerra range of reversed-phase HPLC columns. Purchasing the Xterra Shield RP18 Column will enable you to quickly enhance peak shape performance for really simple compounds. A general-purpose, hybrid-based, reversed-phase C18 column using Waters' unique embedded polar group technology makes up the lab equipment. When compared to a silica-based column, the first-generation XTerra Shield RP18 column offers greater pH stability. The XTerra Shield RP18 Column, like other lab equipment made by Waters, is produced under ISO 9001 guidelines, guaranteeing that every step is carried out to the highest standards and tightest tolerances. Directly from our online store, you can choose products that are most suited to your analytical requirements and purchase lab equipment . The Waters XTerra Shield RP18 offers many advantages over the traditional silica columns that are currently on the market. These include the capacity to customize particle size, pore diameters, surface area, purity, extremely spherical shape, mechanical strength, and surface chemistry. The lab equipment uses conventional bonding agents to do this. Additionally, it makes it possible for the XTerra Shield RP18 column, a vital piece of all-purpose lab equipment, to maintain high separation efficiency, give optimal shape performance for extremely basic chemicals, and enhance pH stability. With the XTerra Shield RP18 Column, you may work with a variety of pH levels. Invest in the XTerra Shield RP18 VanGuard Cartridge, 125Å, 5 µm, 2.1 mm X 5 mm, 3/pk , which prevents any chemical or particulate matter from entering the mobile stream, increasing the accuracy of the analysis while extending the lifetime of the column.

FAQ
What Is The Carbon Load Of The XTerra Shield RP18 Column? The XTerra Shield RP18 Column listed here offers a carbon load of 15%. What Is The Maximum Pressure That The XTerra Shield RP18 Column Is Designed For? This particular XTerra Shield RP18 Column has been designed to tolerate a maximum of 6000 psi (415 Bar) pressure.

Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924