BRAND / VENDOR: Waters

Waters, 186006170, XSelect  HSS  C18 SB XP Column, 100 Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg

CATALOG NUMBER: 186006170
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

The XSelect HSS C18 SB column is a low coverage, unendcapped C18 phase used for low pH separations that contain complex mixtures of basic and non-basic compounds. XSelect HSS C18 SB columns give you alternative analyte selectivity compared to most modern, high coverage, fully endcapped C18 stationary phases. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Temperature Limits: 45 C
Maximum Pressure: 10000 psi (690 Bar)
Endcapped: No
Bonding Technology: C18 SB
Silanol Activity: High
Particle Shape: Spherical
Particle Size: 2.5 µm
Endfitting Type: Parker-style
Pore Size: 100 Å
Format: Column
Surface Area: 230
System: UPLC, UHPLC
Particle Technology: HSS
USP Classification: L1
Inner Diameter: 4.6 mm
Length: 75 mm
Carbon Load: 8.5 %
UNSPSC: 41115709
Brand: XSelect
Product Type: Columns
Units per Package: 1 pk

Additional Information
XSelect HSS C18 SB XP Column, 100 Å, 2.5 µm, 4.6 mm X 75 mm, 1/pkg For low pH separations, including intricate blends of basic and non-basic chemicals, the XSelect HSS C18 SB column is a low coverage, non-end-capped C18 phase. In contrast to the majority of contemporary, high coverage, completely end-capped C18 stationary phases, XSelect HSS C18 SB columns offer alternative analyte selectivity. A seamless transition path to UPLC adoption is made possible by the inclusion of 2.5 µm eXtended Performance [XP] columns in ultra-low dispersion hardware, which provides superior separation performance, resilience, and throughput for HPLC tests. Several particle technologies are needed to handle complex samples and enable a complete chromatographic analysis of various food types and other substances. Waters has created a wide range of laboratory equipment, including columns that make use of unique, distinctive, and exclusive particle technologies, to guarantee excellent operating stability in your lab. You can get around any chromatographic challenges by using properly selected ligands to complement the CSH and HSS technologies in Waters products. Waters' HSS—High Strength Silica technology was used to construct the XSelect HSS C18 SB Column, which was developed to improve the chromatographic performance of "Ethylene Bridged Hybrid" (BEH) and "Charged Surface Hybrid" (CSH) particles. The XSelect HSS C18 SB Column's properties let it withstand UPLC pressures, enabling it to give additional advantages in your system, including different selectivity and greater polar compound. This makes it fully scalable and transferable to UPLC separations. If you're looking to expand your collection of lab supplies or would like to explore the full selection of tools that Waters offers, please browse around our website or look through our catalog to shop for lab equipment . Compatible with the XSelect HSS C18 SB XP Column, you may be interested in checking out XSelect HSS C18 SB XP VanGuard Cartridge, 100Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk ; By eliminating particle pollution from the mobile phase stream, XSelect HSS C18 SB VanGuard Cartridges are used to increase analytical column lifetime and performance. All 4.6 mm I.D. XSelect HSS C18 SB analytical columns with 2.5 µm sorbent particles are protected by this cartridge.

FAQ
What Causes My LC System To Always Stop Down? To enhance system security, safeguard the columns and equipment, and assure system safety, HPLC pumps and systems come with an overpressure setting. The pump may stop working in order to safeguard the LC system if your system is operating at too low a setting or there is too much back pressure. Other factors could include the need for line cleaning or the removal of debris that has accumulated or crystallized and is obstructing or choking the system.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.