30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 1 pH
pH Range Max: 12 pH
Temperature Limits: 80 C (Low pH)/60 C (High pH)
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 5 µm
Pore Size: 130 Å
Format: Prep Guard Cartridge
Surface Area: 185
System: HPLC Preparative
Particle Technology: BEH
Technique: LC/MS, LC
USP Classification: L1
Inner Diameter: 30 mm
Length: 10 mm
Carbon Load: 18 %
UNSPSC: 41115709
Brand: XBridge
Product Type: Guards
Units per Package: 1 pk

Additional Information
XBridge BEH C18 Prep Guard Cartridge, 130Å, 5 µm, 30 mm X 10 mm, 1/pk Waters produces all analytical columns, VanGuards, and Prep Guard columns and cartridges with the same matching chemistry and particle size between the injector and main columns. XBridge BEH C18 Prep Guard Cartridge has been designed specifically for use with the Waters UPLC columns for reversed-phase Liquid Chromatography. The VanGuard Cartridge is a single unit whose design allows it to be attached directly to the inlet side of a Waters XBridge UPLC Column. XBridge BEH C18 Prep Guard Cartridge is easy to install and convenient to use. It ensures that your XBridge BEH C18 Column is protected from damaging contaminants. By filtering out any chemical and particulate impurities that may be present in the mobile phase stream, the lab equipment enhances and improves the column’s analytical performance. Ensure that your XBridge BEH C18 analytical columns last longer without compromising their chromatographic analytical performance by connecting them to the XBridge BEH C18 Prep Guard Cartridge. The Cartridge maintains the columns’ UPLC, UHPLC, and HPLC separation efficiency while removing chemical and particulate contaminants from the columns. It is important to use a high-performance matching prep guard column to protect your system and main column, while not compromising or changing the analytical resolution. You can rely on the Waters XBridge BEH C18 Prep Guard Cartridge to consistently achieve superb quality and desired results as required for liquid chromatography. Similar to all equipment produced by Waters, these columns are manufactured in dedicated state-of-the-art Waters facilities. All Water manufacturing plants and facilities follow the strictest cGMP, ISO 9001 conditions. Each step of the manufacturing process is carefully monitored and controlled so you rest assured you have the highest quality equipment in your labs. Find various products that are compatible with the XBridge BEH C18 Prep Guard Cartridge, including VanGuards, vials, elution plates from our website. The website enables you to shop for lab equipment , as well as to reach out with any queries you may have. You can direct these queries and concerns to a member of our staff, located in one of our numerous offices located globally. You may also be interested in the Preparative Chromatography Mix Standard; the Quality Control Reference Material portfolio is a unique collection of standards and mixtures. It enables the user to evaluate and benchmark their chromatography system before analysis of a critical material. The Preparative Chromatography Mix Standard is 5 mg/mL each of Diclofenac sodium salt, Diphenhydramine hydrochloride, and Flavone in DMSO. This standard mix should be used to confirm the benchmark performance of your Preparative/purification system.

FAQ
What Is The Importance Of Resolution In Chromatography? Optimizing separations in chromatography can be achieved by utilizing resolution measurements, as resolution is directly influenced by two inherent properties of the chromatographic process: peak width and retention time. Resolution is a quantitative indicator of the separation efficiency and refers to the degree of separation between adjacent peaks. By manipulating the peak width and retention time, it becomes possible to enhance the resolution and achieve better separation of components in a mixture. Therefore, resolution measurements serve as a valuable tool for fine-tuning and optimizing chromatographic separations.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924