Product Description
CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.
Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Temperature Limits: 45 C
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: Yes
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 1.6 µm
Endfitting Type: Parker-style
Pore Size: 90 Å
Format: Column
Surface Area: 100
System: UPLC, UHPLC
Particle Technology: Solid Core
USP Classification: L1
Inner Diameter: 2.1 mm
Length: 150 mm
Carbon Load: 6.6 %
eCord: Yes
UNSPSC: 41115709
Brand: CORTECS
Product Type: Columns
Units per Package: 1 pk
Additional Information
CORTECS Solid Core C18 Column, 90Å, 1.6 µm, 2.1 mm X 150 mm, 1/pk Benefit from the solid-core particle technology to maximize efficiency for maximum resolution with the CORTECS Solid Core C18 Column. The column is the perfect lab equipment as its higher efficiency gives you increased resolution for analyzing complex samples when compared to fully porous columns. This general-purpose column offers balanced retention of acids, bases, and neutrals at low and mid-range pH. By simply raising the flow rate of the method, the CORTECS Solid Core C18 Column enables you to increase sample throughput with comparable or better peak capacities. The analytical column also makes it possible to use shorter column length compared to the original separation while maintaining similar peak capacities and providing faster re-equilibration time. The CORTECS Solid Core C18 Column enables you to decrease the cost of analysis and lab operations as you can run more samples at the same time and get results faster. This is made possible due to its speed of analysis without compromising separation performance. Each step of the manufacture of the CORTECS Solid Core C18 Column is tightly monitored and controlled to ensure that the analytical column gives unparalleled reproducibility and consistent performance year after year. Protect your analytical column and ensure its long lifetime by using the shop for lab equipment , and check all related products and other variants of the same listing as well as our complete range of products, browse through our catalog.
FAQ
What Solvents Can Be Used With The CORTECS Solid Core C18 Column? Always use high-quality HPLC or MS grade solvents to maintain maximum column performance. Filter all aqueous buffers prior to use through a 0.2 µm filter. As a general rule, solvents containing suspended particulate materials will clog the outside surface of the inlet of the column. This may result in higher backpressure or distorted peak shape.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmation.
3. Minimum order value of $1,000 USD required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924