Product Description
CORTECS T3 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. CORTECS T3 analytical columns containing 2.7 µm sorbent particles.
Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: Yes
Bonding Technology: T3
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 2.7 µm
Endfitting Type: Parker-style
Pore Size: 120 Å
Format: VanGuard Cartridge
Surface Area: 100
System: UPLC, UHPLC
Particle Technology: Solid Core
USP Classification: L1
Inner Diameter: 3.9 mm
Length: 5 mm
Carbon Load: 4.7 %
eCord: Yes
UNSPSC: 41115709
Brand: CORTECS
Product Type: Guards
Units per Package: 3 pk
Additional Information
CORTECS T3 VanGuard Cartridge, 120Å, 2.7 µm, 3.9 mm X 5 mm, 3/pk Use the CORTECS T3 VanGuard Cartridges to protect your column from degeneration and extend its life. CORTECS T3 VanGuard Cartridges are used to enhance the lifetime and performance of analytical columns by eliminating particle pollution from the mobile phase stream. The lab equipment works properly with the CORTECS T3 column because it is built of the same packing material. The VanGuard Cartridge is a piece of protective equipment that lies between the injector and the analytical column, keeping chemical pollutants and suspended particles out. Because it is built with the same high-performance packing materials used in all Waters analytical columns, you can be confident that the CORTECS T3 VanGuard Cartridges will perform and protect your Waters analytical column for a long period. The pre-column was designed specifically for scenarios that necessitate more capacity for biological fluid purification and/or temperature control. The CORTECS T3 VanGuard Cartridges, like all Waters equipment, is manufactured in a cGMP, ISO 9001 certified plant using ultra-pure chemicals. Furthermore, CORTECS T3 VanGuard Cartridges packing material is chromatographically tested with acidic, basic, and neutral analytes, and the results are held to the highest standards to assure outstanding, consistent performance. Additionally, each pre-column is tested and authorized for its specific use, assuring that it will perform optimally and improve the selectivity, sensitivity, and speed of your study. You can evaluate all of Waters' options and shop for lab equipment based on your laboratory needs by browsing our catalog or visiting our website. You might also be interested in Neutrals QC Reference Material . The Neutrals QC Reference Material is intended for use with any chromatographic system equipped with a UV detector. Its purpose is to serve as a system benchmarking standard. The mixture exclusively comprises neutral chemicals. The QC Reference Material, when used consistently and control documented, will provide confidence in your results, decrease troubleshooting and re-run time, and enable cross-laboratory result comparisons. This reference material can be used with a wide range of separation procedures.
FAQ
How Does Filtration Work In A Laboratory Setting? Draw around 1 mL of air into the syringe before filling it with a sample. This allows air to escape from the syringe along with the sample. This "air purge" aids in the retention of less fluid by the filter mechanism. Next, fill the syringe with the filtered solution. Twist the loaded syringe to the filter device while holding the filter device in one hand (without using too much force). Apply gentle pressure to begin filtering.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmation.
3. Minimum order value of $1,000 USD required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924