Product Description
CORTECS Shield RP18 columns provides complimentary selectivity to C8 and C18 stationary phases. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. The solid core particle morphology offers high efficiency and lower backpressures when compared to fully porouse particles of similar particle size.
Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Temperature Limits: 45 C
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: Yes
Bonding Technology: Shield RP18
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 2.7 µm
Endfitting Type: Parker-style
Pore Size: 90 Å
Format: Column
Surface Area: 100
System: UPLC, UHPLC
Particle Technology: Solid Core
USP Classification: L1
Inner Diameter: 2.1 mm
Length: 150 mm
Carbon Load: 6.4 %
eCord: Yes
UNSPSC: 41115709
Brand: CORTECS
Product Type: Columns
Units per Package: 1 pk
Additional Information
CORTECS Shield RP18 Column, 90Å, 2.7 µm, 2.1 mm X 150 mm, 1/pk The CORTECS Shield RP18 Column is made to be versatile and produce high-efficiency results, bringing about significant advantages. The solid-core particle used in the lab equipment provides balanced retention of acids, bases, and neutrals at low and mid-range pH levels. Even at low pH levels, these characteristics lead to the delivery of outstanding peak shape for basic analytes. Quickly resolve complicated combinations or retain resolution while improving throughput by using the all-purpose CORTECS Shield RP18 Column. Due to the solid-core particles' improved performance in lowering each of the three terms of the van Deemter equation, the column is able to produce excellent results. The B term is dropped because the solid core particles have lower particle porosity, which reduces axial diffusion, while the A term is lowered because the solid core particles pack more uniformly. Their solid core enhances heat transport, lowering radial temperature gradients, which lowers the C term. Use the CORTECS Shield RP18 Column in analyses when you need supplementary selectivity to the C8 and C18 stationary phases. When compared to straight-chain alkyl columns, the lab equipment can be used to achieve alternate selectivity since it makes use of an embedded carbamate group in the bonded phase ligand. The CORTECS Column's solid core particle shape delivers great efficiency and lower back pressures as compared to totally porous particles of comparable particle size. We recommend that you also explore and invest in the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk . TruView LCMS Certified Glass Vials use a production procedure that minimizes adsorption. High recoveries of polar analytes are produced by this technique because the circumstances limit the concentration of free ions on the glass surface. Using a number of methods, including LC/UV and UPLC/MS, all vials are extensively evaluated for dimensional features, chemical purity, and adsorption.
FAQ
What Is The Maximum Pressure Recommended For The CORTECS Shield RP18 Column? The CORTECS Shield RP18 Column listed here is able to sustain a maximum of
18000 psi (1240 Bar) pressure. Across What pH Range Does The CORTECS Shield RP18 Column Operate? This particular Waters CORTECS Shield RP18 Column is able to work well within the 2-8 pH range.