Waters, 186009231, Dextran Standards Kit

CATALOG NUMBER: 186009231
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

Eight vials containing 500 mg/vial of dextrans at each molecular weights: 1,000, 4,400, 8,500, 15,000, 30,000, 50,000, 87,000, 225,000 (approximate values)

Specifications
Separation Mode: GPC/GFC/SEC
Detection Method: RI
Formulation: Solid
Storage Condition: Solid
System Type: LC
Instrument: APC
Shelf Life: 60 Months
Shelf life upon reconstitution: 1 Week
Tracibility: No
Shipping Condition: Ambient
Tolarence: 10% (Mp)
Mass: 500 mg Each
Type: Calibration
UNSPSC: 41116107
Application: Gel Filtration
Product Type: Standard Kits
Units per Package: 1 pk

FAQ
How Do I Perform Filtration? Draw approximately 1 mL of air into the syringe before filling the syringe with a sample. This will allow the air to follow the sample out of the syringe. This “air purge” minimizes fluid retention within the filter device. Next, fill the syringe with the solution to be filtered. Holding the filter device in one hand, secure (without excessive force) the filled syringe to the filter device with a twisting motion. Apply gentle pressure to begin filtration. What Is Sensitivity In Chromatography? Sensitivity is the signal output per unit concentration, or unit mass of a substance in the mobile phase entering the detector, e.g., the slope of a linear calibration curve. Sensitivity is also the ratio of peak height to the analyte concentration in the peak for concentration-sensitive detectors. It is the ratio of peak height to unit mass in mass-flow-sensitive detectors. For sensitivity to be a unique performance characteristic, it must depend only on the chemical measurement process, not on scale factors. The ability to detect (that is, qualify) or measure (that is, quantify) an analyte is dependent on many instrumental and chemical factors. In the ideal scenario, well-resolved peaks elute from high-efficiency columns (narrow peak width with good symmetry for maximum peak height). This is in addition to good detector sensitivity and specificity. To achieve maximum sensitivity, both the separation system interference and electronic component noise should also be minimized.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924