Product Description
The Atlantis Premier BEH C18 AX Columns provide excellent retention for polar acidic analytes under reversed phase conditions. The reversed phase/anion-exchange mixed mode chemistry is stable from pH 2-10, and has complimentary selectivity to traditional C18 stationary phases, which is desirable when doing methods development.
Specifications
Chemistry: RP/Anion-exchange
Separation Mode: Mixed mode
Particle Substrate: Hybrid
pH Range Max: 10 pH
Temperature Limits: 60 C
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: Yes
Bonding Technology: C18 AX
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 2.5 µm
Endfitting Type: Parker-style
Pore Size: 95 Å
Format: Premier Column
Surface Area: 270
System: UPLC, UHPLC
Particle Technology: BEH
Technique: LC
USP Classification: L78
Inner Diameter: 4.6 mm
Length: 100 mm
Carbon Load: 17 %
UNSPSC: 41115709
Brand: Atlantis
Product Type: Columns
Units per Package: 1 pk
Additional Information
Atlantis Premier BEH C18 AX Column, 2.5 µm, 4.6 x 100 mm, 1/pk To get excellent retention for polar acidic analytes under reversed-phase conditions, add the Atlantis Premier BEH C18 AX Column to your lab equipment collection. The column uses reversed-phase, anion-exchange, mixed-mode chemistry that is stable from pH 2-10. In addition to this, it has complementary selectivity to traditional C18 stationary phases, which is desirable when doing method development. These attributes make the Atlantis Premier BEH C18 AX Column a highly sought-after lab equipment by chromatography scientists. The Atlantis Premier BEH C18 AX Column uses MaxPeak™ High-Performance Surfaces technology, which is an innovative technology that has been designed specifically by Waters to increase analyte recovery, sensitivity, and reproducibility by minimizing analyte/surface interactions that can lead to sample losses. This makes the Atlantis PREMIER BEH C18 AX Column a great piece of lab equipment that not only gives reliable, consistent analysis results, but one that is also highly efficient and enables you to prepare and use as many samples as required. You can browse through our complete portfolio and find suitable lab equipment that works in conjunction with the Atlantis PREMIER BEH C18 AX Column, using our catalog or Waters online store. The Atlantis Premier BEH C18 AX Column is produced in a cGMP, ISO 9001 certified plant using ultra-pure reagents. In addition to this, to ensure product quality, each batch is tested chromatographically, and the results are held to narrow specification ranges to assure excellent, reproducible performance. To make sure that you receive only quality products from Waters, every Atlantis Premier BEH C18 AX Column is individually tested, and a Performance Chromatogram and Certificate of Batch Analysis are provided in the column box or on the eCord™ Intelligent Chip. The Certificate of Analysis is specific to each batch of packing material and includes the batch number, analysis of unbonded particles, analysis of bonded particles, and chromatographic results and conditions. The Performance Test Chromatogram is also specific to each individual column and contains the batch number, column serial number, USP tangent efficiency, USP tailing factor, retention factor, and chromatographic conditions. Waters recommends that these data should be stored for future reference. You may also want to explore and purchase the Neutrals QC Reference Material.
FAQ
What Pressure Can The Atlantis Premier BEH C18 AX Column Sustain? The Atlantis Premier BEH C18 AX Column mentioned in this context demonstrates an impressive pressure tolerance of up to 18,000 psi (1240 Bar).