Product Description
As the column for method development, ACQUITY Premier BEH C18 Columns provides you with the most universal column choice for high performance separations. MaxPeak High Performance Surface hardware technology significantly reduces unwanted analyte/surface interactions that can lead to poor peak shape and losses in signal intensity. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), which is ideal for methods development.
Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 1 pH
pH Range Max: 12 pH
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: Yes
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 1.7 µm
Endfitting Type: Parker-style
Pore Size: 130 Å
Format: Premier Column
Surface Area: 185
System: UPLC
Particle Technology: BEH
Technique: LC
USP Classification: L1
Inner Diameter: 2.1 mm
Length: 50 mm
Carbon Load: 18 %
eCord: Yes
UNSPSC: 41115709
Brand: ACQUITY
Product Type: Columns
Units per Package: 1 pk
Additional Information
ACQUITY Premier BEH C18 Column, 1.7 µm, 2.1 x 50 mm, 1/pk The ACQUITY Premier BEH C18 Column is the choice column for method development for scientists the world over. It provides you with the most universal column choice for high-performance separations. The lab equipment uses the Waters MaxPeak High Performance Surface hardware technology, which significantly reduces unwanted analyte/surface interactions that can lead to poor peak shape and losses in signal intensity. In addition to this, the trifunctionally bonded BEH particle presented in the ACQUITY Premier BEH C18 Column gives you the widest usable pH range (pH 1-12), which is ideal for methods development. Use the ACQUITY UPLC BEH C18 Column in order to deliver outstanding performance with unprecedented levels of efficiency, peak symmetry, and chemical stability. The 1.7 µm lab equipment is the premier column for method development whose sorbent provides you with the most universal column choice for UPLC separations. As the analytical lab equipment uses the tri-functionally bonded BEH particle, it can be used as a universal method development tool and has been designed to be used across a wide range of analytes. Utilize the column for the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications. The use of the ACQUITY UPLC BEH C18 Column makes it possible for you to easily impact the retention, selectivity, and sensitivity of ionizable compounds. One reason that the lab equipment is able to deliver exceptional results is that the packing materials used in it have been designed specifically for use with the ACQUITY UPLC System. In addition to this, the analytical column shows improved efficiency, strength, and pH range by fully harnessing the power of BEH Technology, which is a key enabler of the speed, sensitivity, and resolution offered by the analytical columns. This results in the rapid and robust development of separations. The column is produced in a cGMP, ISO 9001 certified plant using ultra-pure reagents, like all the lab equipment that is manufactured by us. We recommend that you store your samples and analytes safely and securely in the chemically inert LCMS Certified Clear Glass 12 x 32 mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septum, 1 mL Volume, 100/pk. What makes the ACQUITY Premier BEH C18 Column ideal for method development? The column features Waters' MaxPeak High Performance Surface technology and BEH particle chemistry, providing a wide pH range (1–12), excellent peak shape, and low analyte loss, making it one of the most universal tools for UPLC method development. Can this column be used for LC-MS applications? Yes, it offers ultra-low column bleed, superior low pH stability, and high efficiency, making it ideal for high-sensitivity mass spectrometry (MS) workflows. What hardware system is this column compatible with? This column is engineered specifically for use with Waters ACQUITY UPLC Systems, ensuring optimal performance and reproducibility in your UPLC separations.
FAQ
What Is The Carbon Load Of The ACQUITY UPLC BEH C18 Column? The ACQUITY UPLC BEH C18 Column listed here carries a carbon load of 18%.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmation.
3. Minimum order value of $1,000 USD required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924