Product Description
Spherisorb ODS1 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS1 packing features low ligand density with a specified carbon load of 6.2%.
Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: No
Bonding Technology: ODS1
Silanol Activity: High
Particle Shape: Spherical
Particle Size: 10 µm
Endfitting Type: Parker-style
Pore Size: 80 Å
Format: Column
Surface Area: 220
System: HPLC
USP Classification: L1
Inner Diameter: 4.6 mm
Length: 200 mm
Carbon Load: 6 %
UNSPSC: 41115709
Brand: Spherisorb
Product Type: Columns
Units per Package: 1 pk
Additional Information
Spherisorb ODS1 Column, 80Å, 10 µm, 4.6 mm X 200 mm, 1/pk Add the Spherisorb ODS1 Column to your lab equipment collection to meet all the liquid chromatography challenges of your lab. The analytical column is reliable as it is a general-purpose, silica-based, reversed-phase C18 column and designed to handle a wide range of applications. The packing of the Spherisorb ODS1 Column uses a low ligand density with a specified carbon load of 6%, as researchers and scientists at Waters realize the criticality of the way a chromatographic column is packed. The packing helps address four very important performance features, including peak symmetry, column efficiency, column lifetime, and column-to-column reproducibility. Additionally, you can be certain of the column’s performance as the column packing processes used by Waters are developed to ensure maximum performance at all times. Our goal is always to develop and deliver a column that is best suited to and can perform on all aspects of liquid chromatography, and it is important to understand the effect of all process parameters such as slurry solvent choice, packing pressure, time, temperature, flow rate, and slurry volume. This is why extensive research and analysis is conducted by the Waters R&D engineers to develop a packing process for each product we offer. The resulting products are available for you to purchase from us, with the guarantee that they can be relied upon to get the best peak symmetry, highest column efficiency, and best column stability. To make sure that you have proof of the column’s quality, each Spherisorb ODS1 Column is individually tested, and a copy of the test chromatogram is supplied with each column. Be sure to explore through our website and catalog, which contain more information on all our brands and help you to directly shop for lab equipment from us. We recommend that you also invest in the Spherisorb ODS1 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pk , to protect your analytical column’s performance.
FAQ
Why Are Buffers Used In HPLC? It is necessary to control the pH of the mobile phase by the addition of a buffer as the retention of ionizable compounds is very sensitive to the mobile phase pH. A buffer maintains the pH when a small amount of acid or base is added. Many different substances can be used for buffering in HPLC.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmation.
3. Minimum order value of $1,000 USD required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924