Waters, PSS845280, Spherisorb C8 Column, 80Å, 5 µm, 4 mm X 125 mm, 1/pk

CATALOG NUMBER: PSS845280
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

Specifications
Chemistry: C8
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Silanol Activity: Medium
Particle Shape: Spherical
Particle Size: 5 µm
Endfitting Type: Parker-style
Pore Size: 80 Å
Format: Column
Surface Area: 220
System: HPLC
USP Classification: L7
Inner Diameter: 4 mm
Length: 125 mm
Carbon Load: 6 %
UNSPSC: 41115709
Brand: Spherisorb
Product Type: Columns
Units per Package: 1 pk

Additional Information
Spherisorb C8 Column, 80Å, 5 µm, 4 mm X 125 mm, 1/pk Get exceptional flexibility in enhancing procedures and reducing solvent use by using the Spherisorb C8 Column. The la equipment is a general-purpose, silica-based, reversed-phase C8 column with a defined carbon load of 6 percent, and a moderate Octyl ligand density packing. The preparation column was created to be used for general purposes and is a reliable, highly effective piece of chromatographic equipment that can handle a variety of applications. When you need a less retentive sorbent than Spherisorb ODS columns, opt for this USP L7 lab equipment. The Spherisorb C8 Column satisfies all of your standards for liquid chromatography quality. The lab equipment is produced in a special Waters' chromatography chemistry manufacturing facility that follows the tightest cGMP and ISO 9002 guidelines when synthesizing and packing silica-based and polymeric chromatography materials into columns and solid-phase extraction devices. Due to your efforts, you can be certain that the lab equipment you receive is of the highest caliber and will produce reliable analytical results on a constant basis. You receive the most crucial performance characteristics when you utilize the Spherisorb C8 Column in your lab, including column efficiency, peak symmetry, column lifetime, and column-to-column repeatability. You can explore the complete range of Spherisorb columns developed by Waters to meet your various analysis needs by exploring our website. The site also enables you to shop for lab equipment. Waters created the Spherisorb C8 Column after a substantial study that identified and addressed the implications of all process parameters, including the choice of slurry solvent, packing pressure time, temperature, flow rate, and slurry volume. To guarantee that the lab equipment performs at its best every time, the results of this intensive research are mirrored in the column packing procedures employed in its construction. As a result, you also get the best peak symmetry and the highest column stability and efficiency. We recommend that you protect your column by using the Spherisorb C8 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 10 mm, 3/pk.

FAQ
Across What pH Range Does The Spherisorb C8 Column Operate? The Spherisorb C8 Column listed here offers an operating pH range of 2-8 pH. What Is The Maximum Pressure That The Spherisorb C8 Column Can Sustain? This particular Spherisorb C8 Column is able to work well with a max of 6000 psi (415 Bar) pressure. However, pressure less than the maximum limit is recommended to ensure that the column continues to deliver its optimal efficiency and lasts a long time.