BRAND / VENDOR: Waters

Waters, WAT086342, Nova-Pak C18 Radial-Pak Column, 60Å, 4 µm, 8 mm X 100 mm, 1/pk

CATALOG NUMBER: WAT086342
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Temperature Limits: 45 C
Maximum Pressure: 1500 psi (100 Bar)
Endcapped: Yes
Silanol Activity: Medium
Particle Shape: Spherical
Particle Size: 4 µm
Pore Size: 60 Å
Format: Radial-Pak Column
Surface Area: 120
System: HPLC Preparative
Technique: LC/MS, LC
USP Classification: L1
Inner Diameter: 8 mm
Length: 100 mm
Carbon Load: 7 %
UNSPSC: 41115709
Brand: Nova-Pak
Product Type: Columns
Units per Package: 1 pk

Additional Information
Nova-Pak C18 Radial-Pak Column, 60Å, 4 µm, 8 mm X 100 mm, 1/pk Use the Nova-Pak C18 Radial-Pak Column in your lab to get higher resolution and faster, more efficient chromatography. The lab equipment’s shorter length makes it possible to use less solvent consumption while maintaining the resolution needed for complex mixtures, maximizing efficiency in the lab. It also makes the wait time shorter. The general-purpose, silica-based, reversed-phase C18 Nova-Pak C18 Radial-Pak Column is based on the 4 µm particle technology and can be depended upon for nearly any system configuration, sample type, and instrument platform. Compared to a 5 µm column, Nova-Pak C18 Radial-Pak Column offers higher resolution, more efficient separations, and faster chromatography. Using the Nova-Pak C18 Radial-Pak Column, you will find that there is more interaction time between the elutes and the bonded phase, making it possible for the sample to elute more slowly and allow more separation. This is because of the larger surface area offered by the lab equipment for the mobile phase to travel across. The 4µ particle technology, on which the Nova-Pak C18 Radial-Pak Column is based, makes it possible for the lab equipment to provide an unparalleled range of possibilities for separation and high efficiency and carbon surface area. In addition to this, it enables you to leverage faster separations to produce more concentrated fractions, which, combined with less solvent consumption, significantly reduces laboratory operating costs. The bonded phases offered by the Nova-Pak C18 Radial-Pak Column facilitate high resolution and fast, efficient analysis. The smaller particles used in the column reduce solvent consumption without compromising the ability to resolve complex mixtures. In addition to this, the Nova-Pak C18 Radial-Pak Column comes equipped with Waters proprietary end caps for optimal security and ease of use. Like all Waters lab equipment, the strictest quality control processes are used in the manufacturing of the Nova-Pak C18 Radial-Pak Column. Every step is carefully monitored throughout to ensure a high level of batch-to-batch reproducibility and to deliver the optimum quality that is the hallmark of Waters. Learn more about our manufacturing processes and the complete range of lab equipment that we carry through our website. We recommend that you also invest in the system benchmarking Reversed-Phase QC Reference Material .

FAQ
What pH Range Is Recommended For The Nova-Pak C18 Radial-Pak Column? The Nova-Pak C18 Radial-Pak Column listed here offers an operating pH Range of 2-8.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924